Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab
This paper details the design, reconstruction, and commissioning of the cryogenic and purification systems for the ICARUS T600 detector, which was relocated from Gran Sasso to Fermilab and upgraded for operation with high-intensity neutrino beams to search for sterile neutrinos and measure neutrino-argon cross sections.