← Latest papers
🔬 physics

An aerogel Knudsen pump for motionless evaporative cooling of liquid helium below 4 K

This paper presents a motionless, temperature-gradient-driven aerogel Knudsen pump that enables vibration-free evaporative cooling of liquid helium below 4 K, offering a quiet cryogenic solution for quantum technologies by achieving significant pressure differentials and helium flow rates without mechanical components.

Original authors: Changzhao Pan, Tiantian Xiao, Yu Zhang, Jianqiao Wang, Shu Guo, Jianbo Tang

Published 2026-11-25
📖 5 min read🧠 Deep dive

Original authors: Changzhao Pan, Tiantian Xiao, Yu Zhang, Jianqiao Wang, Shu Guo, Jianbo Tang

Original paper licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). ✨ This is an AI-generated explanation of the paper below. It is not written or endorsed by the authors. For technical accuracy, refer to the original paper. Read full disclaimer

Deep within the laboratories where the world's most sensitive quantum computers and superconducting sensors live, a constant battle is fought against the slightest disturbance. These machines require temperatures colder than the depths of outer space to function, often relying on liquid helium to reach those extremes. To keep the helium cold, scientists must continuously remove the gas that naturally evaporates from its surface. Traditionally, this has been done with mechanical vacuum pumps. However, these machines are noisy, both in sound and in vibration. That vibration can travel through the cooling system and jostle delicate quantum bits, causing errors in calculations or blurring the results of precise measurements. For years, researchers have sought a way to pump away this gas without any moving parts, hoping to create a silent, vibration-free environment. The solution they have long looked for relies on a phenomenon called thermal transpiration, where a temperature difference across a tiny, porous material can push gas molecules from a cold side to a hot side, creating a flow without any mechanical fan or piston.

A team of researchers has now successfully built and tested a device that uses this principle to cool liquid helium, marking a significant step toward motionless refrigeration. They constructed a pump using a specialized material called polyimide aerogel, a substance so light and porous that it is mostly empty space, filled with a network of microscopic channels. When they placed this aerogel between a cold section and a warm section, the temperature difference alone was enough to drive helium gas through the tiny pores. The gas moved from the cold end toward the warm end, effectively sucking vapor away from the liquid helium and lowering its pressure. This drop in pressure caused the remaining liquid to cool down further, a process known as evaporative cooling. The device operated entirely without moving parts, proving that a simple temperature gradient could replace the noisy mechanical pumps that have been standard for decades.

The researchers began by characterizing the unique properties of their polyimide aerogel. This material is exceptionally good at insulating heat, meaning it can maintain a steep temperature difference between its two ends without the heat leaking through and equalizing them. This is crucial because the strength of the pumping effect depends on how large that temperature gap is. They found that the aerogel's thermal conductivity was hundreds of times lower than that of the ceramic materials previously used in similar experiments. This allowed them to establish a strong temperature gradient even at the frigid temperatures of liquid helium. When they tested the device, they observed that it could generate a significant pressure difference, pushing gas from the cold side to the hot side. In one test, with a temperature difference of about 14 degrees, the pump created a pressure difference of roughly 10,000 pascals. In other tests, they measured how much gas the pump could move, finding it could transport over 100 micromoles of helium every second when there was no back pressure resisting the flow.

To make the pump powerful enough for real-world cooling applications, the team connected multiple stages of the aerogel pump together in a series. They developed a mathematical model to predict how these stages would work together, which they verified by testing a two-stage setup. The results showed that connecting the pumps in a line increased the total pressure difference they could generate, while connecting them side-by-side increased the volume of gas they could move. Using this knowledge, they built a four-stage pump and integrated it into a system designed to cool liquid helium. Before turning on the pump, the liquid helium in their container was at a temperature of 3.61 Kelvin. Once they activated the motionless pump, it began to draw vapor away from the liquid. Over the course of 27 hours, the pressure above the liquid dropped steadily, and the temperature of the liquid helium fell to 3.13 Kelvin. This represents a cooling of nearly half a degree, achieved entirely by the movement of gas through the porous aerogel, driven only by the temperature difference between the cold and warm ends of the device.

The experiment demonstrated that thermal transpiration can sustain the continuous extraction of helium vapor required for evaporative cooling. The pressure and temperature of the liquid followed the expected physical relationship for helium, confirming that the cooling was indeed caused by the removal of vapor. While the cooling rate was modest compared to what large mechanical pumps can achieve, the result proves the concept is viable. The device operated silently and without vibration, offering a potential path forward for cooling systems where mechanical noise is unacceptable. The researchers noted that future improvements could focus on increasing the flow area and optimizing the structure of the aerogel to handle larger heat loads. This work suggests that the temperature difference, often considered a nuisance in cryogenic systems, can be harnessed as a direct source of refrigeration. By replacing mechanical pumps with a simple, solid-state device, scientists may soon be able to build quantum computers and sensors that operate in a truly quiet, vibration-free environment.