Zernike-efficient phase contrast with a scanned electron probe

The paper proposes APEX, a scanned-probe imaging mode that utilizes a defocused probe and a π/2\pi/2 phase element to achieve Zernike-efficient phase contrast, enabling superior phase reconstruction and depth separation of weak-phase objects compared to conventional 4D-STEM and single-exposure Zernike phase-contrast CTEM.

Original author: Philipp Pelz

Published 2026-11-18
📖 6 min read🧠 Deep dive

Original author: Philipp Pelz

Original paper licensed under CC BY 4.0 (http://creativecommons.org/licenses/by/4.0/). ✨ This is an AI-generated explanation of the paper below. It is not written or endorsed by the author. For technical accuracy, refer to the original paper. Read full disclaimer

In the quiet world of electron microscopy, scientists use beams of electrons to see the smallest structures in nature, from the intricate folds of proteins to the atomic lattices of crystals. For decades, a fundamental problem has limited how clearly these machines can see biological samples. Because these samples are so delicate, the electron beam can damage them if too many electrons are used. To get a clear picture, researchers need to extract the maximum amount of information from every single electron that hits the sample. This is particularly difficult when trying to see "weak-phase" objects, which are transparent materials that do not absorb electrons but instead slightly slow them down, creating a subtle shift in the wave of the electron beam. Traditional methods often struggle to capture this subtle shift without blasting the sample with a dose of electrons that would destroy it.

To solve this, researchers have developed a technique called Zernike phase contrast, which uses a special filter to turn those invisible shifts in the electron wave into visible brightness differences. This method works beautifully when the electron beam is a wide, parallel sheet of light, but it has historically been much less efficient when using a focused, scanning beam, which is the standard for modern high-resolution imaging. A new study proposes a way to bridge this gap, combining the precision of a scanning beam with the efficiency of the phase-contrast filter. The researchers, led by Philipp Pelz at Friedrich-Alexander-Universität Erlangen-Nürnberg, have designed a new imaging mode called APEX. Through detailed computer simulations, they show that this method can capture nearly all the phase information available from each electron, a feat that current scanning techniques cannot match, potentially allowing scientists to see biological molecules with unprecedented clarity and minimal damage.

The core of this new approach lies in how the electron beam is focused and where the special filter is placed. In a standard scanning microscope, a lens focuses a beam of electrons into a tiny spot that scans across the sample. In the APEX method, the researchers deliberately defocus this beam, meaning the electrons are not focused directly onto the sample but converge to a point slightly above or below it. As the beam passes through the sample, the electrons that do not hit any atoms continue straight, while those that interact with the sample are scattered slightly to the side. The genius of the design is placing a microscopic phase-shifting element, which acts like a tiny dot, exactly at the point where the unscattered electrons would converge if they were allowed to continue. This dot shifts the phase of the unscattered electrons just enough to make them interfere with the scattered ones, creating a high-contrast image. Crucially, the detector does not look at the scattered pattern far away; instead, it captures a sharp, magnified image of the sample right after this interaction, at every single position the beam scans.

The researchers tested this idea by simulating the imaging of myoglobin, a common protein found in muscle, embedded in a layer of frozen water that mimics the conditions of cryo-electron microscopy. They compared their new APEX method against the best existing techniques, including a sophisticated scanning method known as four-dimensional scanning transmission electron microscopy, or 4D-STEM. The simulations showed that APEX, using an ideal phase-shifting dot, reconstructed the shape of the protein more accurately than the 4D-STEM method, even when the 4D-STEM was given a very generous amount of data. The new method was able to transfer almost all the available information from the electrons to the final image, whereas the older scanning method lost a significant portion of that information. This suggests that for weak, delicate samples, APEX could provide a much clearer view with the same low dose of electrons, or the same clarity with even fewer electrons, reducing the risk of damage.

The study also explored how this method could be used to see through the thickness of a sample, a capability known as depth sectioning. Because the electron beam in APEX is defocused, it illuminates the sample from a range of angles as it scans. This creates a situation similar to taking a series of pictures of an object from slightly different angles, but all in a single scan without moving the sample. The researchers simulated a scenario with two layers of protein separated by a distance of 150 nanometers. While a standard microscope image would blur these two layers into one indistinguishable mass, the APEX simulation successfully separated them, revealing the distinct structure of each layer. This separation was achieved in a single scan, a feat that a standard microscope cannot do without physically tilting the sample, which is often difficult and can introduce errors.

To make this work in a real microscope, the researchers identified specific hardware requirements. They found that the phase-shifting element needs to be placed at a magnified image of the beam's focus point, which requires additional lenses to enlarge that tiny spot so it can be resolved by the filter. They also compared different types of filters, including an idealized theoretical dot and a more practical version using crossed laser beams. The simulations showed that while a perfect dot offers the best performance, a laser-based filter can come very close to that performance if the beam is defocused by a specific amount, roughly 25 micrometers. At this larger defocus, the laser filter acts almost exactly like the ideal dot, allowing the microscope to capture images that are nearly as good as those taken with a stationary, non-scanning beam.

The paper concludes that while the method has been proven in simulations, it has not yet been built and tested in a physical microscope. The researchers outline the optical challenges that must be overcome, such as keeping the beam perfectly aligned with the tiny phase-shifting element as it scans across the sample. They also note that for the method to work at the highest resolutions, the microscope would need to correct for certain optical distortions that currently blur the image. Despite these hurdles, the study provides a clear roadmap for a new way of seeing. By rethinking where the phase filter sits and how the beam is focused, APEX offers a path to extracting more information from fewer electrons, which could revolutionize the study of fragile biological structures that are currently too small or too sensitive to be seen clearly.