Impact of Successive Earthquakes on Incremental Structural Damage during the 2025 Sındırgı, Türkiye Earthquake Doublets
This study analyzes two adjacent reinforced concrete buildings in Sındırgı, Türkiye, following the 2025 earthquake doublets to demonstrate how pre-existing damage and reinforcement detailing deficiencies interact to cause the total collapse of one structure while the other remained standing.
Original paper licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). This is an AI-generated explanation of the paper below. It is not written or endorsed by the authors. For technical accuracy, refer to the original paper. Read full disclaimer
Earthquakes rarely happen in isolation. The ground often shakes, settles, and then shakes again, sometimes with devastating force, before the dust has even fully cleared. For decades, engineers have designed buildings to withstand a single, massive jolt, assuming that if a structure survives that one event, it is safe. However, a growing body of evidence suggests that the interval between quakes is often too short for a building to recover. When a second strong tremor hits a structure that has already been weakened by the first, the damage does not simply add up; it compounds. The building enters the second event with reduced strength and stiffness, making it far more likely to fail than it would have been if it had been standing in perfect condition. This phenomenon, known as cumulative damage, turns a sequence of earthquakes into a unique and dangerous test of a building's true resilience.
In the Sındırgı district of western Türkiye, researchers found a rare opportunity to study this process in real life. In August 2025, a magnitude 6.1 earthquake struck the region, causing widespread damage to the local building stock. Just two and a half months later, in October of the same year, a second earthquake of nearly identical strength struck the exact same area. This "doublet" event provided scientists with a natural laboratory to observe how buildings that had already survived one major shock fared against a second. The researchers focused on two neighboring reinforced concrete buildings, which looked almost identical in their design and had both been classified as heavily damaged after the first quake. Yet, when the second earthquake hit, one of these buildings collapsed completely, while its neighbor, despite suffering further degradation, remained standing. By combining field inspections with detailed computer simulations, the team uncovered exactly why these two similar structures met such different fates.
The investigation began with a close look at the ground shaking itself. The two main earthquakes, though similar in overall strength, delivered their energy in slightly different ways. The first quake shook the ground with longer, slower waves, while the second delivered sharper, faster jolts that were particularly demanding for low-rise buildings. When the researchers examined the damage across the entire district, a clear pattern emerged. The vast majority of the severe damage and collapses occurred in older buildings constructed before the year 2000, particularly those made of unreinforced masonry or concrete built with poor quality materials. Newer buildings, constructed under stricter codes, fared much better, with almost none suffering heavy damage. However, the most revealing part of the study focused on the two adjacent concrete buildings, labeled B9 and B10. Both were built in the early 1990s and shared a critical flaw: their ground floors were open for shops, leaving them without the stiff walls that the upper floors had. This created a "soft story," a weak point where the building was likely to bend and break during an earthquake.
After the first earthquake, both buildings were heavily damaged, with cracked columns and crushed concrete, but they were still standing. The researchers noted that while they looked similar, there were subtle but critical differences in their construction. Building B10 had slightly stronger concrete and more steel reinforcement in its columns than Building B9. When the second earthquake struck, the difference in their fate became stark. Building B9, which had the weaker materials and more irregular design, lost its ability to support its own weight and collapsed. Building B10, though severely damaged and left with a permanent tilt, held together. The computer models confirmed that the first earthquake had already weakened the structure of Building B9 so significantly that the second shock pushed it past the point of no return. The damage from the first event had shifted the building's natural rhythm, making it resonate more violently with the shaking of the second quake, effectively amplifying the forces it had to endure.
The study also looked at the role of the brick walls that fill the spaces between the concrete frames. In many buildings, these walls are not considered part of the structural support, but the simulations showed they played a vital role in the early stages of the shaking. The walls acted like stiffeners, reducing the amount the buildings swayed and delaying the onset of collapse. In Building B10, the presence of these walls helped the structure survive the second earthquake, whereas a model of the same building without the walls would have collapsed. However, the researchers found that these walls are a temporary shield; as the shaking continued and the bricks cracked and crumbled, they lost their strength, and the full burden of the earthquake was transferred back to the already weakened concrete frame. This means that while the walls might save a building from a single event, they cannot protect a substandard structure from a sequence of strong quakes.
The findings from Sındırgı offer a sobering lesson for earthquake safety. The research demonstrates that a building which appears stable after a major earthquake may be on the verge of failure if another strong tremor follows soon after. The damage from the first event is not just a cosmetic issue; it fundamentally alters how the building responds to future shaking, often making it more vulnerable to collapse. The study suggests that current safety protocols, which often assess buildings based on a single event, may be underestimating the risk in regions prone to earthquake sequences. For older buildings with known weaknesses, such as soft ground floors or poor construction quality, the margin for error is dangerously thin. The survival of Building B10 was not a sign of safety, but rather a narrow escape, while the collapse of Building B9 served as a stark reminder that cumulative damage can turn a survivable event into a catastrophe. The researchers conclude that after a major earthquake, especially in an area where aftershocks or a second main shock are possible, the assessment of damaged buildings must be far more conservative, recognizing that the structure's capacity to withstand further shaking has likely been permanently and severely diminished.