This study demonstrates through 1/20-scale shaking table tests that a surface-installed weight collar effectively mitigates absolute liquefaction-induced manhole uplift, though residual protrusion and groundwater conditions remain critical factors for post-earthquake functionality, leading to the proposal of a three-step screening procedure for prioritizing retrofit sites.

Original authors: Khin Nyein Chan Kyaw, Daiki Fujita, Shinya Inazumi

Published 2026-11-27
📖 4 min read☕ Coffee break read

Original authors: Khin Nyein Chan Kyaw, Daiki Fujita, Shinya Inazumi

Original paper licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). ✨ This is an AI-generated explanation of the paper below. It is not written or endorsed by the authors. For technical accuracy, refer to the original paper. Read full disclaimer

When the ground beneath a city shakes, the soil can sometimes lose its strength and behave like a thick liquid, a phenomenon known as liquefaction. In this state, heavy structures like buildings may sink, but lighter objects buried underground, such as the hollow concrete shafts that serve as access points to sewer systems, can float upward. This happens because the liquefied soil acts like a dense fluid that pushes up on anything lighter than itself. When these manholes rise, they can break through the asphalt of a road, creating a sudden obstacle that blocks emergency vehicles during a crisis and tears apart the pipes that carry wastewater away. Because these structures are buried beneath busy streets, fixing them before an earthquake is difficult; digging them up to reinforce them would require closing roads for days and disturbing other underground utilities.

Researchers at Shibaura Institute of Technology have explored a simpler, faster way to keep these manholes in place. Instead of digging deep trenches to change the soil, they tested a method that adds weight directly to the top of the manhole from the road surface. By placing heavy concrete rings and a layer of mortar around the neck of the manhole, just below the pavement, they hoped to make the structure heavy enough to resist the upward push of the liquefied ground. To see if this idea works, the team built small-scale models of standard sewer manholes and placed them in a box filled with loose, wet sand. They then shook the box to simulate an earthquake, comparing a standard manhole with one that had been retrofitted with the heavy collar.

The experiments revealed a clear difference between the two. When the sand liquefied, the standard manhole without extra weight floated upward, rising between 9.6 and 14.0 millimeters. This movement was significant enough to be measured as a percentage of the model's height. In contrast, the manhole with the heavy collar did not rise at all. The added weight successfully held it down against the buoyant force of the shaking sand. However, the story did not end with the manhole staying perfectly still. Because the loose sand around the models settled and compacted after the shaking stopped, the ground level dropped by about 11 to 14 millimeters. Since the weighted manhole stayed put while the ground sank, it still ended up sticking out of the road surface, though only by about half the amount of the unweighted one. This distinction is crucial: while the collar prevented the manhole from floating up, it could not stop the surrounding road from sinking, meaning the manhole would still create a bump on the street, just a smaller one.

The researchers analyzed the forces at play to understand why the collar worked. They found that the added weight increased the manhole's resistance to floating, but the benefit depended heavily on where the groundwater was located. In their tests, the water table was at the very surface, which is the worst-case scenario for this type of retrofit. When the heavy collar is submerged in water, the water pushes up on the collar itself, canceling out some of the weight it was meant to add. The calculations suggested that if the groundwater level is deeper, the collar remains dry and its full weight helps hold the manhole down. If the water is high, the collar acts more like a boat, and its ability to keep the manhole down is greatly reduced. The team proposed a screening process for cities to decide where this retrofit is useful: it should be prioritized for manholes on critical emergency routes, but only if the local groundwater is deep enough to keep the collar dry.

The study concludes that this surface-installed weight collar is a promising tool for preventing the most severe damage, which is the manhole breaking through the road entirely. It offers a way to strengthen existing infrastructure quickly without the massive disruption of deep excavation. Yet, the researchers are careful to note that this is not a perfect fix. The method stops the manhole from rising, but it does not stop the ground from settling, so a small bump may still remain. Furthermore, the tests were conducted on small models in a controlled environment, and the real-world behavior of full-sized manholes connected to complex pipe networks under different soil conditions remains to be fully proven. The work suggests a practical path forward for disaster mitigation, provided that engineers carefully check the local water levels and understand that the goal is to minimize damage rather than eliminate it entirely.