Intra-rater within-session and inter-rater reliability of MyotonPRO® and IndentoPRO for assessing abdominal wall viscoelastic and biomechanical properties in late postpartum women

This study demonstrates that both the MyotonPRO® and IndentoPRO devices exhibit acceptable intra- and inter-rater reliability for assessing abdominal wall viscoelastic and biomechanical properties in late postpartum women, with the MyotonPRO® showing superior consistency between raters and potential utility for clinical and research applications in postpartum rehabilitation.

Original authors: Luiza Z. Fanti, Fabiana C. Silva, Chiara M. Vasconcelos, Robert Schleip, Renata Salomão, Ronaldo H. Cruvinel-Júnior, Marcelo Faria Silva

Published 2026-06-29
📖 4 min read☕ Coffee break read

Original authors: Luiza Z. Fanti, Fabiana C. Silva, Chiara M. Vasconcelos, Robert Schleip, Renata Salomão, Ronaldo H. Cruvinel-Júnior, Marcelo Faria Silva

Original paper licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). This is an AI-generated explanation of the paper below. It is not written or endorsed by the authors. For technical accuracy, refer to the original paper. Read full disclaimer

Imagine your abdominal wall (the "six-pack" area) as a complex, stretchy trampoline made of fabric and springs. During pregnancy, this trampoline gets stretched out, and sometimes the center seam (called the linea alba) gets a bit loose or separated. This condition is known as Diastasis Recti Abdominis (DRA).

For a long time, doctors have mostly checked this by measuring the width of the gap between the muscles, like measuring the distance between two fence posts. But the authors of this paper argue that knowing the gap size isn't enough; we also need to know how "bouncy," "stiff," or "stretchy" the fabric itself feels.

To check this "feel," the researchers tested two portable gadgets on 62 women who were 8 to 24 months after giving birth. They wanted to see if these gadgets gave consistent, reliable readings when used by the same person twice in a row (intra-rater) and when used by two different people (inter-rater).

Here is how the two gadgets worked and what they found:

The Two Gadgets

  1. MyotonPRO® (The "Tapping Detective"):

    • How it works: Think of this as a high-tech drumstick. It gently taps the skin and listens to how the tissue vibrates back, like a drum. It measures things like how tight the tissue is (stiffness), how fast it relaxes, and how bouncy it is.
    • The Result: This gadget was a star performer. Whether the same person used it three times in a row, or two different people used it, the results were almost identical. It was like having two different chefs use the same precise scale to weigh flour; they got the exact same number every time. The paper calls this "excellent reliability."
  2. IndentoPRO (The "Gentle Press"):

    • How it works: This gadget is like a controlled thumb press. It pushes down into the skin to a specific depth and measures how much force is needed to get there. It's testing how hard it is to squish the tissue.
    • The Result: This gadget was good, but a bit finicky. When the same person used it repeatedly, they got very consistent results (good-to-excellent reliability). However, when two different people used it, the results varied more. It was like two different people trying to press a button with the "exact same force" by hand; one might press slightly harder than the other, changing the reading. The paper found this gadget had "moderate-to-good" reliability between different people.

What the Study Actually Says (and Doesn't Say)

  • The "Late Postpartum" Factor: The study focused on women who were several months to two years post-baby. They found that even this long after birth, many women still had a wide gap (DRA) and some had a "bulge" when they lifted their heads.
  • The "Fat" Rule: The researchers had a strict rule: if a woman had more than 20mm of fat under her skin, they couldn't use the gadgets. It's like trying to hear a whisper through a thick wool blanket; the signal gets lost.
  • The Main Takeaway: The paper concludes that these tools are reliable for measuring the mechanical properties (stiffness, bounce, etc.) of the belly wall in these women.
    • MyotonPRO is so consistent that different doctors could use it on the same patient and trust the numbers would match.
    • IndentoPRO is reliable if the same person does the testing, but different people need to be very careful to use the exact same technique to get matching numbers.

What the Paper Does NOT Claim

It is important to stick to what the authors actually wrote:

  • They did not say these gadgets can cure DRA or fix the gap.
  • They did not say these gadgets are better than ultrasound for measuring the width of the gap (ultrasound is still the gold standard for that).
  • They did not claim that using these tools will automatically improve a woman's recovery or quality of life.
  • They did not say these tools should replace all other methods.

Instead, the paper simply says: "If you want to measure how stiff or stretchy the belly tissue is, these gadgets work well and give consistent numbers, especially the MyotonPRO." This consistency is the first step before doctors can start using these numbers to make treatment plans in the future.